5%Carbowax 20M Carbopack B填充柱 頂空-填充柱氣相色譜法測定氣樣中甲醇
產(chǎn)品名稱:5%Carbowax 20M Carbopack B填充柱 頂空-填充柱氣相色譜法測定氣樣中甲醇
產(chǎn)品型號:5%Carbowax 20M Carbopack B填充柱
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
簡單介紹
頂空-填充柱氣相色譜法測定氣樣中甲醇,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內(nèi)空氣,焦爐煤氣,煉廠氣,天然氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,塑化劑,過氧化物
5%Carbowax 20M Carbopack B填充柱 頂空-填充柱氣相色譜法測定氣樣中甲醇的詳細介紹
頂空-填充柱氣相色譜法測定氣樣中甲醇
頂空-填充柱氣相色譜法測定氣樣中甲醇 詳細信息:
名稱:填充柱
頂空-填充柱氣相色譜法測定氣樣中甲醇 詳細信息:
名稱:填充柱
色譜固定液:5%聚乙二醇
載體:石墨炭黑80-120目
規(guī)格:2m*3mm,2m*1/8
型號:5%Carbowax 20M Carbopack B
應(yīng)用: HJ T33-1999 固定污染源排氣中甲醇的測定氣相色譜法
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司對自動頂空進樣器與氣相色譜法聯(lián)用技術(shù)測定環(huán)境空氣和廢氣中甲醇的方法進行了研究.結(jié)果表明:當樣品加入4 g氯化鈉,項空平衡溫度為80 ℃,平衡時間為20 min,用5%Carbowax 20M Carbopack B填充柱分離,氫火焰離子化檢測器檢測時,得到甲醇標準曲線方程為y=23 415x+237.2,相關(guān)系數(shù)(R)0.9994;檢出限為0.002 mg/m3,相對標準偏差(n=6)為0.5%,加標回收率為98.9%.該方法簡單、靈敏、分離度好、檢出限低.
頂空-填充柱氣相色譜法測定氣樣中甲醇 測試譜圖:
頂空-填充柱氣相色譜法測定氣樣中甲醇 測試譜圖:
Determination of Methanol in Gas Samples by Headspace-Packed Column Gas Chromatography
Determination of methanol in gas samples by headspace-packed column gas chromatography. Details:
Name: Packed column
Chromatographic statio nary liquid: 5% polyethylene glycol
Carrier: Graphite carbon black 80-120 mesh
Specification: 2m*3mm, 2m*1/8
Model: 5% Carbowax 20M Carbopack B
Application: HJ T33-1999 Determination of Methanol in Exhaust from Statio nary Pollution Sources Gas Chromatography
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. has carried out research on the method of automatic headspace sampler combined with gas chromatography for the determination of methanol in ambient air and exhaust gas. The results show that when the sample is added with 4 g of sodium chloride, the item The air equilibrium temperature is 80 ℃, and the equilibrium time is 20 min. It is separated with a 5% Carbowax 20M Carbopack B packed column. When detected by a hydrogen flame io nization detector, the methanol standard curve equation is y=23 415x+237.2, and the correlation coefficient (R ) 0.9994; the detection limit is 0.002 mg/m3, the relative standard deviation (n=6) is 0.5%, and the recovery rate of standard addition is 98.9%. The method is simple, sensitive, good resolution, and low detection limit.
Headspace-packed column gas chromatography for the determination of methanol in gas samples Test spectrum:
Determination of methanol in gas samples by headspace-packed column gas chromatography. Details:
Name: Packed column
Chromatographic statio
Carrier: Graphite carbon black 80-120 mesh
Specification: 2m*3mm, 2m*1/8
Model: 5% Carbowax 20M Carbopack B
Application: HJ T33-1999 Determination of Methanol in Exhaust from Statio
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. has carried out research on the method of automatic headspace sampler combined with gas chromatography for the determination of methanol in ambient air and exhaust gas. The results show that when the sample is added with 4 g of sodium chloride, the item The air equilibrium temperature is 80 ℃, and the equilibrium time is 20 min. It is separated with a 5% Carbowax 20M Carbopack B packed column. When detected by a hydrogen flame io
Headspace-packed column gas chromatography for the determination of methanol in gas samples Test spectrum: