Tenax-TA吸附管熱銷中 室內(nèi)空氣中TVOC分析
產(chǎn)品名稱:Tenax-TA吸附管熱銷中 室內(nèi)空氣中TVOC分析
產(chǎn)品型號:Tenax-TA吸附管熱銷中
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
簡單介紹
室內(nèi)空氣中TVOC分析,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內(nèi)空氣,焦?fàn)t煤氣,煉廠氣,天然氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,氨水,氨氣,醫(yī)療器械,環(huán)氧乙烷
Tenax-TA吸附管熱銷中 室內(nèi)空氣中TVOC分析的詳細(xì)介紹
室內(nèi)空氣中TVOC分析
室內(nèi)空氣中TVOC分析 詳細(xì)信息:
由于室內(nèi)空氣污染的日趨嚴(yán)重,室內(nèi)空氣檢測越來越受到人們的關(guān)注。結(jié)合實際檢測工作,針對GB50325-2001《民用建筑工程室內(nèi)環(huán)境污染控制規(guī)范》和GB/T18883-2002《室內(nèi)環(huán)境質(zhì)量標(biāo)準(zhǔn)》檢測苯和TVOC的不足,對分析方法作了較深入的研究,自制了采樣管低溫控制裝置、低溫玻璃珠除濕裝置,實現(xiàn)了一次采樣、一次進(jìn)樣同時得到苯和TVOC的準(zhǔn)確分析數(shù)據(jù)。
另外,根據(jù)檢測需要,配制了VOCs液態(tài)標(biāo)準(zhǔn)物質(zhì),研究了制作標(biāo)準(zhǔn)系列管的條件。 GB50325-2001和GB/T18883-2002中規(guī)定的熱解吸,毛細(xì)管氣相色譜法,在現(xiàn)場應(yīng)用Tenax吸附管的采樣條件中,規(guī)定采樣流量為0.5L/min,采樣時間為20min,沒有規(guī)定采樣溫度,實驗操作條件不明確或不甚合理,影響到測定結(jié)果的準(zhǔn)確性和重現(xiàn)性。
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司對此進(jìn)行了深入研究,發(fā)現(xiàn)采樣管溫度、采樣流量和采樣時間對苯系物的吸附回收率都有明顯的影響。 發(fā)現(xiàn)空氣中的濕度條件對VOCs回收率影響也很大,在實際采樣過程中發(fā)現(xiàn),僅控制采樣管的溫度,苯的回收率不到90%,而且在低溫采樣時,經(jīng)常使得FID檢測器熄火。通過在采樣管前增加一低溫玻璃珠管來除濕,取得很好的效果。 采用低溫玻璃珠除濕、控制吸附管采樣溫度為5℃左右、采樣流量在200mL/min、采樣時間10min,并用二次熱解吸儀直接注入氣相色譜,在以上采樣條件下,可以TVOC所有組分的吸附熱解吸回收率都可以達(dá)到90%以上,特別是苯的采樣回收率有很大的提高。
室內(nèi)空氣中TVOC分析 測試譜圖:
TVOC analysis in indoor air
Analysis of TVOC in indoor air Details:
As indoor air pollution is becoming more and more serious, indoor air testing has attracted more and more attention. Combined with actual testing work, in view of the insufficiency of GB50325-2001 "Code for Indoor Enviro nmental Pollution Co ntrol of Civil Co nstruction Engineering" and GB/T18883-2002 "Indoor Enviro nmental Quality Standards" for the detection of benzene and TVOC, a more in-depth study of analytical methods was made, and self-made The sampling tube low-temperature co ntrol device and the low-temperature glass bead dehumidification device can obtain accurate analysis data of benzene and TVOC at the same time for one sampling and one injection.
In addition, according to testing needs, liquid VOCs standard materials were prepared, and the best co nditions for making standard series tubes were studied. The thermal desorption and capillary gas chromatography specified in GB50325-2001 and GB/T18883-2002, in the sampling co nditions of the Tenax adsorption tube used in the field, the sampling flow rate is 0.5L/min, the sampling time is 20min, and the sampling temperature is not specified. , The experimental operating co nditions are unclear or unreasonable, which affects the accuracy and reproducibility of the measurement results.
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. co nducted an in-depth study on this and found that the temperature of the sampling tube, the sampling flow rate and the sampling time all have a significant impact on the adsorption recovery rate of benzene series. It is found that the humidity co nditions in the air also have a great influence on the recovery rate of VOCs. In the actual sampling process, it was found that o nly co ntrolling the temperature of the sampling tube, the recovery rate of benzene was less than 90%, and when sampling at low temperatures, the FID detector was often turned off. . By adding a low-temperature glass bead tube in front of the sampling tube to dehumidify, good results are achieved. Use low-temperature glass beads to dehumidify, co ntrol the sampling temperature of the adsorption tube to a bout 5℃, the sampling flow rate at 200mL/min, and the sampling time for 10min, and use a seco ndary thermal desorption instrument to directly inject into the gas chromatograph. Under the above optimal sampling conditions, TVOC can be guaranteed The recovery rate of adsorption thermal desorption of all compo nents can reach more than 90%, especially the sampling recovery rate of benzene has been greatly improved.
TVOC analysis test spectrum in indoor air:
室內(nèi)空氣中TVOC分析 詳細(xì)信息:
由于室內(nèi)空氣污染的日趨嚴(yán)重,室內(nèi)空氣檢測越來越受到人們的關(guān)注。結(jié)合實際檢測工作,針對GB50325-2001《民用建筑工程室內(nèi)環(huán)境污染控制規(guī)范》和GB/T18883-2002《室內(nèi)環(huán)境質(zhì)量標(biāo)準(zhǔn)》檢測苯和TVOC的不足,對分析方法作了較深入的研究,自制了采樣管低溫控制裝置、低溫玻璃珠除濕裝置,實現(xiàn)了一次采樣、一次進(jìn)樣同時得到苯和TVOC的準(zhǔn)確分析數(shù)據(jù)。
另外,根據(jù)檢測需要,配制了VOCs液態(tài)標(biāo)準(zhǔn)物質(zhì),研究了制作標(biāo)準(zhǔn)系列管的條件。 GB50325-2001和GB/T18883-2002中規(guī)定的熱解吸,毛細(xì)管氣相色譜法,在現(xiàn)場應(yīng)用Tenax吸附管的采樣條件中,規(guī)定采樣流量為0.5L/min,采樣時間為20min,沒有規(guī)定采樣溫度,實驗操作條件不明確或不甚合理,影響到測定結(jié)果的準(zhǔn)確性和重現(xiàn)性。
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司對此進(jìn)行了深入研究,發(fā)現(xiàn)采樣管溫度、采樣流量和采樣時間對苯系物的吸附回收率都有明顯的影響。 發(fā)現(xiàn)空氣中的濕度條件對VOCs回收率影響也很大,在實際采樣過程中發(fā)現(xiàn),僅控制采樣管的溫度,苯的回收率不到90%,而且在低溫采樣時,經(jīng)常使得FID檢測器熄火。通過在采樣管前增加一低溫玻璃珠管來除濕,取得很好的效果。 采用低溫玻璃珠除濕、控制吸附管采樣溫度為5℃左右、采樣流量在200mL/min、采樣時間10min,并用二次熱解吸儀直接注入氣相色譜,在以上采樣條件下,可以TVOC所有組分的吸附熱解吸回收率都可以達(dá)到90%以上,特別是苯的采樣回收率有很大的提高。
室內(nèi)空氣中TVOC分析 測試譜圖:
TVOC analysis in indoor air
Analysis of TVOC in indoor air Details:
As indoor air pollution is becoming more and more serious, indoor air testing has attracted more and more attention. Combined with actual testing work, in view of the insufficiency of GB50325-2001 "Code for Indoor Enviro
In addition, according to testing needs, liquid VOCs standard materials were prepared, and the best co
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. co
TVOC analysis test spectrum in indoor air:
相關(guān)產(chǎn)品
在線留言 |