401脫氧柱應(yīng)用之氧氬氮分離
產(chǎn)品名稱:401脫氧柱應(yīng)用之氧氬氮分離
產(chǎn)品型號:
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
簡單介紹
401脫氧柱應(yīng)用之氧氬氮分離,乙酸乙酯,芝麻香白酒,3-甲硫基丙醇,室內(nèi)空氣,醫(yī)療器械,增塑劑,氨水,氨氣,苯系物,環(huán)氧乙烷,二叔丁基過氧化物,增塑劑,甲縮醛,乙縮醛
401脫氧柱應(yīng)用之氧氬氮分離的詳細介紹
401脫氧柱應(yīng)用之氧氬氮分離
401脫氧柱應(yīng)用之氧氬氮分離 詳細信息:
脫氧柱:
規(guī)格:3m*3mm
粒度:0.4mm-0.8mm
型號:401
應(yīng)用:GB/T 3634.1-2006 氫氣 第1部分 工業(yè)氫
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司采用氣相色譜法測定氫氣中微量氬和氮。進樣后,首先經(jīng)脫氧劑將氧脫除,而后經(jīng)色譜柱使氬、氮組分分離。檢測器輸出的響應(yīng)大小在一定范圍內(nèi)與組分含量成正比。將待測組分的響應(yīng)值與標準樣品中相同組分的響應(yīng)值相比較而定量。
401脫氧柱應(yīng)用之氧氬氮分離 測試譜圖:
Oxygen, Argon and Nitrogen Separation for 401 Deoxygenation
Oxygen, Argon and Nitrogen Separation for 401 Deoxygen Column Application
Deoxygenation column:
Specification: 3m*3mm
Granularity: 0.4mm-0.8mm
Model: 401
Application: GB/T 3634.1-2006 Hydrogen Part 1 Industrial Hydrogen
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. uses gas chromatography to determine trace amounts of argon and nitrogen in hydrogen. After the sample is injected, the oxygen is first removed by a deoxidizer, and then the argon and nitrogen compo nents are separated by a chromatographic column. The respo nse size of the detector output is proportio nal to the compo nent co ntent within a certain range. The respo nse value of the compo nent to be tested is compared with the respo nse value of the same compo nent in the standard sample for quantification.
Test spectrum of oxygen, argon and nitrogen separation applied by 401 deoxidizing column:
401脫氧柱應(yīng)用之氧氬氮分離 詳細信息:
脫氧柱:
規(guī)格:3m*3mm
粒度:0.4mm-0.8mm
型號:401
應(yīng)用:GB/T 3634.1-2006 氫氣 第1部分 工業(yè)氫
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司采用氣相色譜法測定氫氣中微量氬和氮。進樣后,首先經(jīng)脫氧劑將氧脫除,而后經(jīng)色譜柱使氬、氮組分分離。檢測器輸出的響應(yīng)大小在一定范圍內(nèi)與組分含量成正比。將待測組分的響應(yīng)值與標準樣品中相同組分的響應(yīng)值相比較而定量。
401脫氧柱應(yīng)用之氧氬氮分離 測試譜圖:
Oxygen, Argon and Nitrogen Separation for 401 Deoxygenation
Oxygen, Argon and Nitrogen Separation for 401 Deoxygen Column Application
Deoxygenation column:
Specification: 3m*3mm
Granularity: 0.4mm-0.8mm
Model: 401
Application: GB/T 3634.1-2006 Hydrogen Part 1 Industrial Hydrogen
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. uses gas chromatography to determine trace amounts of argon and nitrogen in hydrogen. After the sample is injected, the oxygen is first removed by a deoxidizer, and then the argon and nitrogen compo
Test spectrum of oxygen, argon and nitrogen separation applied by 401 deoxidizing column: