GDX-502填充柱 測(cè)定固定污染源廢氣中非甲烷總烴
如果你感興趣的話,可以電話:0632-5667636
產(chǎn)品名稱:GDX-502填充柱 測(cè)定固定污染源廢氣中非甲烷總烴
產(chǎn)品型號(hào):GDX-502填充柱
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司
簡(jiǎn)單介紹
測(cè)定固定污染源廢氣中非甲烷總烴,液化石油氣,二甲醚,甲醇,甲酸,變壓器油,溶解氣,三甲胺,環(huán)氧乙烷,芝麻香白酒,3-甲硫基丙醇,植物油,脂肪酸,6號(hào)溶劑殘留,口罩,氨水
GDX-502填充柱 測(cè)定固定污染源廢氣中非甲烷總烴的詳細(xì)介紹
測(cè)定固定污染源廢氣中非甲烷總烴
測(cè)定固定污染源廢氣中非甲烷總烴 詳細(xì)信息:
固定相:高分子小球
GDX-502,2m*3mm,2m*4mm,2m*1/8,60-80目
甲烷柱
總烴柱
2m*3mm,2m*4mm,2m*1/8,硅烷化玻璃微球
滕州市浩瀚色譜儀器技術(shù)服務(wù)有限公司,以HJ/T 38-1999為基礎(chǔ),針對(duì)氣相色譜法測(cè)定污染源廢氣中非甲烷總烴存在的諸多問(wèn)題進(jìn)行探討,在總烴出峰峰形、廢氣氧峰值測(cè)定、高沸點(diǎn)物質(zhì)干擾等方面做了研究試驗(yàn)。結(jié)果表明,1ml定量環(huán)容易造成總烴出現(xiàn)平頭峰,改成0.25ml定量環(huán)能得到好的峰形;非甲烷總烴的檢出限為0.04 mg/m~3(以碳計(jì));氧峰值與氧量具有線性關(guān)系,應(yīng)根據(jù)氧量判斷氧峰值大小,而不是統(tǒng)一扣除除烴空氣氧峰值;廢氣中存在高沸點(diǎn)組分時(shí),容易吸附于采樣容器內(nèi)壁,將樣品加熱100℃再測(cè)試可提高該組分的檢出率。
測(cè)定固定污染源廢氣中非甲烷總烴 圖片:
Determination of non-methane total hydrocarbons in fixed source waste gas
Determination of non-methane total hydrocarbons in fixed source waste gas Details:
Stationary phase: polymer pellet
GDX-502, 2m*3mm, 2m*4mm, 2m*1/8, 60-80 mesh
Methane column
Total hydrocarbon column
2m*3mm, 2m*4mm, 2m*1/8, silanized glass microspheres
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd., based on HJ/T 38-1999, discusses the problems of gas chromatography in the determination of non-methane total hydrocarbons in waste gas from pollution sources. Research and tests have been carried out on the determination and interference of high-boiling substances. The results show that the 1ml loop is likely to cause a flat peak in the total hydrocarbons, and a good peak shape can be obtained by changing to a 0.25 ml loop; the detection limit of non-methane total hydrocarbons is 0.04 mg/m~3 (calculated as carbon); It has a linear relationship with the oxygen content. The oxygen peak value should be judged according to the oxygen amount, instead of uniformly deducting the peak of the oxygen removal air. When there is a high boiling component in the exhaust gas, it is easy to adsorb to the inner wall of the sampling container, and the sample is heated to 100 ° C and then tested. The detection rate of the component can be increased.
Determination of non-methane total hydrocarbons in fixed source waste gas
相關(guān)產(chǎn)品
|
80/100 ,,, TDX-02氣相色譜填料
TDX-02氣相色譜填料,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內(nèi)空氣,焦?fàn)t煤氣,煉廠氣,天然氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,塑化劑,消毒劑,氨水 |
|
0.7M*1/8 ,,, 定制甲烷/總烴填充柱
定制甲烷/總烴填充柱,液化石油氣,二甲醚,甲縮醛,乙縮醛,乙醇,室內(nèi)空氣,焦?fàn)t煤氣,煉廠氣,天然氣,變壓器油,多氯聯(lián)苯,植物油,增塑劑,塑化劑,消毒劑,氨水 |
在線留言
|