HH-THC-30 氧氣中總烴的測(cè)定毛細(xì)管柱
產(chǎn)品名稱:HH-THC-30 氧氣中總烴的測(cè)定毛細(xì)管柱
產(chǎn)品型號(hào):HH-THC-30
產(chǎn)品廠商:浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司
簡(jiǎn)單介紹
氧氣中總烴的測(cè)定毛細(xì)管柱,非甲烷總烴,液化石油氣,多氯聯(lián)苯,脂肪酸甲酯,二甲醚,甲醛,甲縮醛,甲醇,乙醇,異丙醇,三甲胺,二甲胺,甲胺
HH-THC-30 氧氣中總烴的測(cè)定毛細(xì)管柱的詳細(xì)介紹
氧氣中總烴的測(cè)定毛細(xì)管柱
氧氣中總烴的測(cè)定毛細(xì)管柱 詳細(xì)信息:
滕州市浩瀚色譜儀器技術(shù)服務(wù)有限公司,提出了用直接進(jìn)樣氣相色譜法進(jìn)行氧氣中總烴含量的測(cè)定,考察了各種柱填充物、氧氣和氮?dú)饬髁考斑M(jìn)樣體積等對(duì)響應(yīng)值的影響。并對(duì)載氣進(jìn)行了選擇,通過樣品實(shí)測(cè)表明,方法的相對(duì)偏差在±5%以內(nèi)。
氧氣中總烴的測(cè)定毛細(xì)管柱 圖片:
Determination of total hydrocarbons in oxygen
Determination of total hydrocarbons in oxygen capillary column Details:
Statio nary phase
Specification: 30m*0.53mm
Model: HH-THC-30
Applications: Ambient air and exhaust gases Technical requirements and test methods for portable mo nitors for total hydrocarbons, methane and non-methane total hydrocarbons (HJ 1012-2018)
Statio nary phase: modified molecular sieve
Specification: 30m*0.53mm*25um
Model: HH-PLOT-Molecular sieve
Application: Technical Requirements and Test Methods for Co ntinuous Mo nitoring System for Non-Methane Total Hydrocarbons from Fixed Sources of Waste Gas (HJ 1013-2018)
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. proposed the determination of total hydrocarbon co ntent in oxygen by direct injection gas chromatography. The effects of various column packings, oxygen and nitrogen flow rates and injection volume on the respo nse value were investigated. . The carrier gas was selected and the measured results showed that the relative deviation of the method was within ±5%.
Determination of Total Hydrocarbons in Oxygen Capillary Columns
氧氣中總烴的測(cè)定毛細(xì)管柱 詳細(xì)信息:
固定相;脫活
規(guī)格:30m*0.53mm
型號(hào):HH-THC-30
應(yīng)用: 環(huán)境空氣和廢氣 總烴、甲烷和非甲烷總烴便攜式監(jiān)測(cè)儀技術(shù)要求及檢測(cè)方法(HJ 1012-2018)
固定相:改性分子篩
規(guī)格:30m*0.53mm*25um
型號(hào):HH-PLOT-Molecular sieve
應(yīng)用:《固定污染源廢氣非甲烷總烴連續(xù)監(jiān)測(cè)系統(tǒng)技術(shù)要求及檢測(cè)方法(HJ 1013-2018)》
滕州市浩瀚色譜儀器技術(shù)服務(wù)有限公司,提出了用直接進(jìn)樣氣相色譜法進(jìn)行氧氣中總烴含量的測(cè)定,考察了各種柱填充物、氧氣和氮?dú)饬髁考斑M(jìn)樣體積等對(duì)響應(yīng)值的影響。并對(duì)載氣進(jìn)行了選擇,通過樣品實(shí)測(cè)表明,方法的相對(duì)偏差在±5%以內(nèi)。
氧氣中總烴的測(cè)定毛細(xì)管柱 圖片:
Determination of total hydrocarbons in oxygen
Determination of total hydrocarbons in oxygen capillary column Details:
Statio
Specification: 30m*0.53mm
Model: HH-THC-30
Applications: Ambient air and exhaust gases Technical requirements and test methods for portable mo
Statio
Specification: 30m*0.53mm*25um
Model: HH-PLOT-Molecular sieve
Application: Technical Requirements and Test Methods for Co
Tengzhou Haohao Chromatography Instrument Technology Service Co., Ltd. proposed the determination of total hydrocarbon co
Determination of Total Hydrocarbons in Oxygen Capillary Columns
相關(guān)產(chǎn)品